Performance Parameters |
|
|
|
|
|
|
Electrical Parameters Rating |
minimum |
maximum |
unit |
IN |
Measurement range (DC/AC) |
±20 |
0 |
±50 |
A |
VOQ |
Static rated output |
50 |
49.8 |
50.2 |
%VDD |
R |
Pull-up or pull-down resistor |
50 |
6 |
100 |
KΩ |
VDD |
Power supply voltage |
+5.0V |
4.5 |
5.5 |
V |
IDD |
Power Supply Current |
10 |
7 |
14 |
mA |
S |
Sensitivity Sensitivity |
40 |
39.4 |
40.6 |
mV/A |
Viso |
Insulation withstand voltage; |
2000AC/ 354DC |
2000VAC/50HZ/1MIN/1mA |
dynamic parameters |
εL |
linearity |
≤±0.5% FS |
|
ΔTVOQ |
Warm drift |
≤0.25A |
-20~+85°C |
Tr |
Response time |
≤6us |
|
BW |
bandwidth |
DC~100kHz |
Min -3DB, 25°C |
General parameters |
Ta |
Working environment temperature |
-20~+85°C |
|
|
|
Ts |
Storage ambient temperature |
-25~+95°C |
|
|
|
W |
weight |
|
|
|
|
|
|
|
|
|
|
|
Execution criteria |
EN50178:1998 |
|
|
|
Model: |
CS46 |
Name: |
Hall Current Sensor |
Main Specifications: |
Dimensions: 46*32*42mm
Rated voltage: DC 5V;
Current measurement range: 0-30A (AC/DC)
Working temperature: -40 ° C ~ 85 ° C; |
Features: |
The product is available in both outer and outer structures, depending on the customer's installation space and structure. The structure with the outer casing is a plug-in type structure, which is convenient to use; the bare plate type is generally installed in the outer casing of the device. The product has the advantages of fast response time, high current measurement accuracy, strong overload capability, good linearity and strong anti-interference ability. |
Applications: |
Hall current sensor is mainly used for isolation and conversion of complex signals such as AC, DC, pulse, etc. The Hall signal principle can make the converted signal directly be AD, DSP, PLC, secondary instrument, etc. Various acquisition devices are directly collected and accepted, widely used in current monitoring and battery applications, inverter power supply and solar power management system, DC screen and DC motor drive, electroplating welding application inverter, UPS servo control and other system current signal acquisition and feedback control. |
|
|
|
|
Product Image
|